Daniel from Malta writes

How do I fix the VectorFog H200SF when it keeps turning off when opening the chemical valve?

I hold the starter then let go and slowly open the chemical valve. When it opens to create a fog the unit looks like its choking and shuts down.... when i retry 2 or 3 times over fire comes out of the front... what can we do pls?

Answer:

According to Vector Fog, if the fuel mixture is too rich that is being used in the H200SF Thermal Fog Machine this can cause the fuel to burn fast and then fire comes out of the nozzle. To fix this issue, they recommend shutting down the fuel valve by following these steps below. You may also contact Vector Fog directly at 1-844-780-6711 for addtional troubleshooting and assistance. 1. Push START button and hold 2. Once fuel burns up, release the START button. 3. Then, push START button again and slowly with other hand start opening up fuel valve.(You will see fuel creeping up the fuel hose, then the machine will try to start.) 4. Choke again and once it catches the right fuel mixture it will begin working properly.  This procedure needs to get done sometimes because customers will move the fuel valve as they operate the machine to give more fuel to the system as it operates, but they forget to return it back to the original position, so when it starts, there is fuel in the system and that's what causes the fire out of nozzle.  This unit should not catch fire if the directions on the manual are followed. This procedure and the knocking procedure are on the manual for referencing. Sometimes when customers get comfortable using the machine, they may overlook small things that can make a big difference. This machine has a pulse jet engine and the fuel air mixture is very important for proper operation.  If you are still having trouble, please call VectorFog directly at 844-780-6711.

Answer last updated on: 07/03/2018

Was this answer helpful to you? Yes No